Dr. Dabber Ghost 2
Optional Goodiez
Dr. Dabber Ghost 2
Product details
About the Dr. Dabber Ghost 2
The Ghost 2 by Dr. Dabber is a high-end portable concentrate vaporizer designed for easy on-the-go sessions and which features a variety of upgrades to improve upon the original Ghost design. 360-degree radial sidewall heating and a ceramic bucket and a fully ceramic and black zirconia airpath provide even and consistent heating, pure flavor, and voluminous clouds. Users can select one of three heating modes to suit their needs and the Ghost 2’s built-in intelligent heating will adjust in real time to each draw to maintain a consistent temperature, flavor, and vapor density.
Features of the Dr. Dabber Ghost 2
- 360-degree radial sidewall heating
- Fully isolated ceramic and black zirconia airpath
- Three dynamic heating modes
- Easy-to-use single button operation with LED indicators and haptic feedback
- 1000 mAh battery and bout 20 cycles per charge
- Pass-through charging
- Temperature range of 420 degrees Fahrenheit to 540 degrees
- Dimensions: Height: 3.5 inches and Width: 1.7 inches
- Weight: 7 ounces
How to use the Dr. Dabber Ghost 2
- Do not dry burn the eChamber. This will help to extend the life of the parts. There should always be a small amount of concentrate material in the eChamber while the vaporizer is in use.
- Load concentrate materials directly into the bottom of the eChamber for the best results and use about a ½ pea sized amount at a time. Overloading restricts the airflow and reduces vapor production.
- Press and hold the power button for 2 seconds to turn the vaporizer on or off.
- Press the button once to show the current temperature selection and press again within 3 seconds to change the temperature.
- Press the button 3 times to change the dynamic heating mode.
- Flip the top open to reveal the heating eChamber and load concentrate materials directly onto the bottom of the heating eChamber and close the top.
- Press the button twice to start a heating cycle. The Ghost 2’s LED will pulse red while heating and will show a steady green and will vibrate when the vaporizer is ready to use.
- Take long, slow draws for thicker, voluminous vapor.
- The heating cycle will run for 30 seconds once the set temperature is reached. To cancel, press the button once during heating or extend the cycle by 15 seconds at anytime by pressing the button twice during the heating process. The Ghost 2 will vibrate to confirm the extension. You may only extend the session to 45 seconds one time.
- Please note that the Ghost 2 makes a buzzing/humming/ticking sound while heating or charging. This is normal for the device.
- The eChamber will season over time which allows the eChamber to produce more vapor with less concentrates. These are not covered by a warranty and will need to be replaced and disposed of over time. The lifespan of an eChamber is about 3-12 months depending on user maintenance. To decide if your eChamber needs to be replaced look for signs of visual darkness, crust, damage, a cracked or broken disc, a burnt taste even after a thorough cleaning, leakage, or a noticeable decrease in cloud production.
- When installing a new eChamber, the Ghost 2 will need to be recalibrated with the new eChamber before the first use. To do this, turn the vaporizer off and allow it to sit unplugged for 15 minutes prior to calibration. The unit and eChamber should both be at room temperature during this process. While the unit is off, press the button four times and hold down the button on the fourth press until the LEDs blink. Green indicates a successful recalibration and red indicates an unsuccessful one. Unsuccessful calibrations may be due to a difference in temperature between the eChamber and vaporizer, unclean electrode connections, or the eChamber not being properly installed. Several attempts to recalibrate may be needed before a success.
- The light will blink white three times when it’s time for the battery to be recharged and will pulse upwards while charging. Once the vaporizer is fully charged the light will stay steady.
- Check battery life by pressing the button four times while the unit is powered on. Green means 70% battery left or more. Yellow means 30%-70%. Red means 30% or lower.
The Ghost 2’s Dynamic Heating Modes
Press the button once to see your current temperature setting and press again within 3 seconds to change the temperature. The light will pulse with the new temperature setting color: purple for 420 degrees Fahrenheit, cyan for 450, yellow for 480, and white for 540.
Lower temperatures are best for maximizing the flavor while higher temperatures boost vapor production.
Press the button 3 times to change your dynamic heating mode and the light will show a pattern which represents the heating mode selected. Downward indicates descent mode, pulse indicates steady mod, and upward indicates ascent mode.
Descent mode- The temperature will slowly decrease after reaching the set temperature to simulate the thermal decay of a banger as it naturally cools over time. This is the default setting.
Steady Mode- The vaporizer will adjust the temperature to hold steady throughout the entire heating cycle and will simulate the feel of an e-rig or pen.
Ascent Mode- The temperature will slowly increase after reaching the selected temperature to simulate the sensation of torching a banger as you inhale.
How to clean the Ghost 2
- Use isopropyl alcohol to clean any residue in and around the eChamber and use a paper dowl dampened with warm water to clean the body of the unit. Isopropyl alcohol may cause the finish on the shell to fade.
- For a deep cleaning, start by removing the mouthpiece, built-in airflow regulator, and silicone top from the vaporizer.
- Pour isopropyl alcohol into a small glass.
- Drop the mouthpiece, silicone top, and airflow regulator into the isopropyl alcohol and ensure they are completely submerged. Allow them to soak for up to 20 minutes.
- Heat the eChamber slightly for about 3-5 seconds and use a dry cotton swab to soak up any residue in and around the eChamber and heating chamber. Then use a cotton swab dampened with alcohol to remove any stubborn residue on the bottom and side walls of the eeChamber. Don’t use too much force when cleaning the inside of the eChamber. Dry heat the eChamber for another 3-5 seconds to evaporate leftover alcohol residue.
- Allow all items to air dry completely before use.
- Reassemble the airflow regulator, silicone top, and mouthpiece.
Ghost 2 Safety information
Fully charge the Ghost 2 before the first use using only the official charging cable included with your vaporizer.
The Ghost 2 has a 15-minute auto-shutoff timer to increase the battery life while the unit is not in use and to protect against accidental button presses while the vaporizer is stored in a bag or pocket.
The Ghost 2 will blink yellow 3 times to indicate a faulty connection with the eChamber of if the eChamber has stopped working correctly. Replace the eChamber to test functionality. eChambers are not covered by a warranty due to these being a disposable part.
Always ensure the eChamber is fully threaded down on the battery. It should be finger tight but not too tight. A loose connection to the battery may cause heating issues.
The airflow regulator being installed incorrectly in the silicone top can cause vapor production issues. Remove and reinstall the airflow regulator in the event of thinner clouds.
Important Notes about The Ghost 2 Portable Vaporizer
We’re sorry but we cannot ship the Ghost 2 internationally. Any international orders will be cancelled and immediately refunded.
